Skip to content
Text “Loti” to 833-962-6682 to join the Loti Labs VIP Group!
Text “Loti” to 833-962-6682 to join the Loti Labs VIP Group!
Safety data sheet

GHRP-6 Safety Data Sheet

16-section GHS safety data sheet for GHRP-6 covering hazard identification, safe handling, storage, exposure controls, transport and disposal. Research use only. Specifications and current certificates of analysis are in the GHRP-6 compound library page.

CAS 87616-84-0Formula C46H56N12O6Molecular weight 873.0 g/molVersion 1.8Revision Oct 22, 2026Document ID LL-SDS-GHRP6-001
Dr. Afroza Begum, PhD
Scientifically reviewed by Dr. Afroza Begum, PhD on . Reviewed for classification, labelling and transport under 29 CFR 1910.1200 and 49 CFR. How we review

Current documentation update

: A corrected GHRP-6 COA is now available, reporting a molecular mass of 873.03 Da. View corrected COA.

The signed SDS below reflects the documentation reviewed at signing. This update is separate from the signed SDS and does not amend its reviewed content or downloadable PDF.

01Identification
Product identifierGHRP-6
Other means of identificationGHRP-6; Growth hormone releasing hexapeptide; PubChem CID 9919153. Loti Labs catalog listing(s) covered by this SDS: GHRP-6 5mg.
CAS number87616-84-0
Molecular formulaC46H56N12O6
SequenceHis-D-Trp-Ala-Trp-D-Phe-Lys-NH2, the published GHRP-6 hexapeptide sequence. The published sequence is stated as the parent-substance identity; the lot Certificate of Analysis controls lot-specific identity.
IUPAC name(2S)-6-amino-2-[[(2R)-2-[[(2S)-2-[[(2S)-2-[[(2R)-2-[[(2S)-2-amino-3-(1H-imidazol-5-yl)propanoyl]amino]-3-(1H-indol-3-yl)propanoyl]amino]propanoyl]amino]-3-(1H-indol-3-yl)propanoyl]amino]-3-phenylpropanoyl]amino]hexanamide
Recommended useResearch laboratory chemical for in-vitro scientific research and development.
Restrictions on useNot for human or veterinary use. Not for food, drug, cosmetic, household, agricultural, clinical, therapeutic, or diagnostic applications.

Supplier details

CompanyLoti Labs
Address1204 S Broad St, Brooksville, FL 34601, United States
Telephone877-LOTI-LAB
Websitehttps://lotilabs.com/
Emergency contactCHEMTREC
Emergency phone800-424-9300 CHEMTREC (USA)
+1-703-527-3887 CHEMTREC (International)
24 hours/day; 7 days/week
02Hazard(s) identification

OSHA classification Not classified as hazardous under the OSHA Hazard Communication Standard based on currently available information. Substance-specific hazard data are limited; the absence of classification must not be interpreted as proof that no hazard exists.

Signal wordNone required
Hazard pictogramsNone required
Hazard statementsNone required by current classification
Hazards not otherwise classifiedToxicological properties have not been fully investigated. Fine powder may cause mechanical irritation. Treat as a potentially bioactive substance of unknown toxicity.
Unknown acute toxicityNo quantitative oral, dermal, or inhalation acute-toxicity data identified.

Precautionary statements · prudent laboratory practice

P261 Avoid breathing dust or aerosols.

P264 Wash hands and exposed skin thoroughly after handling.

P280 Wear protective gloves, protective clothing, and eye protection.

P501 Dispose of contents/container in accordance with applicable regulations.

These are supplemental safe-handling statements for this product, which is not assigned a GHS hazard class on the reviewed evidence.

03Composition / information on ingredients
ComponentCASFormulaMWConcentration
GHRP-6 parent peptide87616-84-0C46H56N12O6873.0 g/molResearch-grade lyophilized peptide; the batch COA reports identity, HPLC purity and peptide content; the counter-ion form is not reported on the COA

This SDS describes the parent-peptide identity shown in the composition table. Lot-specific identity, purity and peptide content are documented on the batch Certificate of Analysis; counter-ion, water and residual-solvent content are not reported on the COA. No excipients or stabilizers are intentionally added to the supplied lyophilized peptide.

04First-aid measures
InhalationMove person to fresh air. Keep at rest. Obtain medical advice if symptoms develop or persist.
Skin contactRemove contaminated clothing. Wash thoroughly with soap and water. Seek medical advice if irritation develops.
Eye contactRinse cautiously with water for at least 15 minutes. Remove contact lenses if easy to do. Continue rinsing. Obtain medical attention if irritation persists.
IngestionRinse mouth. Do not induce vomiting unless directed by medical personnel. Contact a poison center or physician if swallowed or symptoms occur.
Most important symptoms/effectsNo substance-specific clinical data available. Exposure may cause mechanical irritation.
Immediate medical attentionTreat symptomatically. No specific antidote known.
05Fire-fighting measures
Suitable extinguishing mediaWater spray, dry chemical, carbon dioxide, or foam appropriate to the surrounding fire.
Unsuitable extinguishing mediaNo substance-specific restriction identified. Avoid methods that disperse dust.
Specific hazardsOrganic nitrogen-containing solid. Thermal decomposition may generate carbon oxides and nitrogen oxides.
Protective equipmentFirefighters should wear full protective equipment and positive-pressure self-contained breathing apparatus.

Peptide is not known to be flammable but may burn under fire conditions.

06Accidental release measures

Personal precautions

Restrict access. Avoid dust formation and all contact. Ensure adequate ventilation. Wear PPE described in Section 8.

Environmental precautions

Prevent release to drains, sewers, surface water, and soil.

Containment and cleanup

Gently collect without raising dust using suitable tools or a HEPA-filtered vacuum. Place in a sealed, labeled container. Clean affected surfaces and dispose of waste in accordance with Section 13.

07Handling and storage

Precautions for safe handling

Handle as a potentially bioactive research substance of unknown toxicity. Conduct weighing, transfer, and reconstitution in a certified chemical fume hood, ventilated balance enclosure, or other effective containment. Avoid generating or breathing dust or aerosols. Avoid eye, skin, and clothing contact. Do not eat, drink, smoke, or apply cosmetics in work areas. Wash thoroughly after handling. Keep containers closed when not in use.

Storage conditions

Store tightly closed, dry, and protected from light and moisture. For the lyophilized material, follow the storage condition shown on the product label. Long-term storage of dry peptides is commonly at −20 °C or colder; do not assign a shelf life beyond supplier documentation. Allow a cold vial to equilibrate to room temperature before opening to reduce condensation. Aliquot reconstituted solutions to minimize freeze to thaw cycles.

Incompatibilities

Strong oxidizing agents, strong acids, strong bases, excessive heat, moisture, direct sunlight, and ultraviolet light.

08Exposure controls / personal protection

Occupational exposure limits

No OSHA PEL, NIOSH REL, or ACGIH TLV identified for GHRP-6. Maintain exposure as low as reasonably achievable.

Engineering controls

Use local exhaust ventilation or a certified containment device for open handling of powder. Larger-scale work should use closed transfer or glovebox/isolator controls. Provide an accessible eyewash and safety shower. Apply the hierarchy of controls required by site risk assessment.

Personal protective equipment

Eye / face protectionSafety glasses with side shields as a minimum; chemical splash goggles for dust, aerosol, or splash-generating tasks. Face shield over goggles where significant splash potential exists.
Hand protectionDisposable nitrile gloves suitable for dry-solid handling. Inspect before use; change immediately if contaminated, damaged, or degraded. Consider double gloves for neat powder.
Skin protectionLaboratory coat, long trousers, and closed-toe footwear. Add a chemical-resistant apron or disposable coverall for higher-exposure work.
Respiratory protectionNormally unnecessary inside effective containment. If engineering controls cannot prevent airborne particulate exposure, use a NIOSH-approved particulate respirator under a compliant respiratory-protection program (29 CFR 1910.134).
HygieneWash hands after handling and before breaks. Remove contaminated clothing. Decontaminate work surfaces and equipment.

PPE must be selected by the employer based on task-specific hazard assessment, quantity, physical form, and exposure potential.

09Physical and chemical properties
Physical stateSolid
AppearanceLyophilized solid.
ColorNo product-specific data available; the batch COA does not record color.
Odor / odor thresholdNo reliable substance-specific data available
Melting point / freezing pointNo reliable data available
Boiling point / rangeNot applicable / decomposes; no reliable data available
FlammabilityNo reliable data available
Lower / upper explosion limitNo reliable data available
Flash pointNot applicable (solid)
Auto-ignition temperatureNo reliable data available
Decomposition temperatureNo reliable data available
pHNot applicable (dry solid)
Kinematic viscosityNot applicable to solid
SolubilityNo product-specific measured solubility data available
Partition coefficient (n-octanol/water)No experimental data available
Vapor pressureNot determined
Evaporation rateNot applicable (non-volatile solid).
Vapor densityNot determined
Specific gravity / relative densityNot determined
Particle characteristicsNo lot-specific particle-size data available
Molecular weight873.0 g/mol
Molecular formulaC46H56N12O6
Stability in solutionSubject to hydrolytic and oxidative degradation typical of peptides. Protect from light and microbial contamination; use a laboratory-established stability period for the prepared solution.

Physicochemical summary: non-volatile solid with negligible vapor pressure; a sharp melting point is typically not observed because the material chars or decomposes on heating. Flash point and pH are not applicable to the dry solid. Solution pH depends on concentration and buffer.

10Stability and reactivity
ReactivityNo dangerous reaction known under recommended handling and storage conditions.
Chemical stabilityExpected to be stable as dry material when stored as directed; peptide may undergo hydrolytic or oxidative degradation.
Possibility of hazardous reactionsHazardous polymerization is not expected.
Conditions to avoidHeat, moisture, direct sunlight, UV exposure, dust generation, and prolonged exposure to air.
Incompatible materialsStrong oxidizers, strong acids, and strong bases.
Hazardous decomposition productsCarbon monoxide, carbon dioxide, nitrogen oxides, and other irritating or toxic fumes under fire or thermal decomposition conditions.
11Toxicological information

Data limitation: The toxicological properties of GHRP-6 have not been fully characterized. Where an endpoint is marked “Not classified”, the available evidence does not meet OSHA/GHS classification criteria; this does not establish absence of hazard.

Likely routes of exposureInhalation, eye contact, skin contact, and ingestion.
Acute toxicityNo reliable quantitative oral, dermal, or inhalation LD₅₀/LC₅₀ data identified. Not classified based on available data.
Skin corrosion / irritationNo reliable standardized test data identified. Not classified based on available data; mechanical or nonspecific irritation cannot be excluded.
Serious eye damage / irritationNo reliable standardized test data identified. Fine powder may mechanically irritate eyes.
Respiratory / skin sensitizationNo reliable substance-specific data identified. Sensitization cannot be excluded.

11. Toxicological information · continued

Germ cell mutagenicityNo reliable substance-specific data identified. Not classified based on available data.
CarcinogenicityNot listed as a carcinogen by IARC, NTP, or OSHA. Absence from these lists is not evidence of no carcinogenic potential.
Reproductive toxicityNo reliable substance-specific reproductive or developmental toxicity data identified. Not classified based on available data.
STOT, single exposureNo reliable substance-specific data identified. Not classified based on available data.
STOT, repeated exposureNo reliable substance-specific data identified. Not classified based on available data.
Aspiration hazardNot applicable to the supplied solid under normal conditions.
Symptoms related to characteristicsNo substance-specific symptoms established. Dust may cause mechanical irritation.
Delayed / immediate / chronic effectsUnknown; data are insufficient.
Numerical measures of toxicityNo reliable numerical toxicity values available.
Interactive effectsNo information on interactive effects was identified.
Alternative information / methodNo read-across or structure-activity (SAR) information from other chemicals was used; where substance-specific data are unavailable this is stated for each endpoint.
Derived no-effect level (DNEL)No substance-specific DNEL has been derived.
Predicted no-effect concentration (PNEC)No substance-specific PNEC has been derived.
12Ecological information
EcotoxicityNo reliable substance-specific fish, aquatic invertebrate, or algae toxicity data identified. Avoid environmental release.
Persistence / degradabilityNo reliable substance-specific biodegradation data identified. Peptide bonds may undergo environmental degradation; rate and products are unknown.
Bioaccumulative potentialNo measured BCF or log Kow is available. Multiple ionizable groups and high polarity support low expected passive bioaccumulation; no bioaccumulation classification is assigned.
Mobility in soilNo reliable data available.
Other adverse effectsNo reliable data available.

Sections 12 to 15 are included for completeness; OSHA does not enforce their substantive content under Appendix D of 29 CFR 1910.1200.

13Disposal considerations

Waste treatment

Dispose of material, contaminated PPE, and containers through a licensed waste contractor in accordance with federal, state, and local requirements. Do not discharge to drains, sewers, or waterways. Do not reuse empty containers. The waste generator is responsible for determining whether the waste meets hazardous-waste criteria at the time of disposal.

14Transport information
FrameworkUN numberProper shipping nameClassPacking group
U.S. DOTNot assignedNot regulated as dangerous goods*,
IATANot assignedNot regulated as dangerous goods*,
IMDGNot assignedNot regulated as dangerous goods*,

*Based on current intrinsic-hazard information for the parent substance. The stated transport classification applies to the supplied material; quantity-, packaging-, carrier-, and mode-specific consignment requirements apply at shipment.

Environmental hazardsNot listed as a marine pollutant (49 CFR 172.101 Appendix B; IMDG Code). No aquatic-toxicity data meeting the UN environmentally hazardous substance criteria were identified for the product.
Transport in bulkNot applicable. The product is supplied in non-bulk packagings and is not transported in bulk under IMO instruments (MARPOL Annex II / IBC Code).
Special precautionsProtect from heat, moisture, light, and physical damage. Maintain required product-label storage conditions.

Transport determination: this solid product does not meet the criteria of a U.S. DOT, IATA or IMDG dangerous-goods class and is not regulated as dangerous goods in the supplied form.

15Regulatory information

Jurisdiction: this SDS is prepared for supply and use in the United States under the OSHA Hazard Communication Standard (29 CFR 1910.1200). Active ingredient CAS number(s) assessed: 87616-84-0. U.S. TSCA: no exact CAS match on that public inventory (87616-84-0); confidential identities are not visible in the public file. California Proposition 65: no exact active-ingredient CAS match on the official list dated July 31, 2026. CERCLA/SARA: no listed component was identified under 40 CFR 302.4 or 40 CFR 372.65 in the reviewed public records; threshold and release-reporting duties remain quantity- and use-dependent. Sources checked: EPA TSCA non-confidential Inventory (July 2026), OEHHA Proposition 65 list (July 31, 2026), 40 CFR 302.4 and 40 CFR 372.65. Public-inventory status is not product approval or authorization.

16Other information
Document IDLL-SDS-GHRP6-001
REVISION DATE2026-10-22
VERSION1.8
Prepared forLoti Labs
BasisOSHA Hazard Communication Standard, 29 CFR 1910.1200, including Appendix D; OSHA HCS 2024 alignment (primarily GHS Revision 7). Jurisdiction: United States; Section 14 covers U.S.-origin shipments under 49 CFR, the IATA Dangerous Goods Regulations and the IMDG Code.
Revision historyRevision 1.8 (2026-10-22): final line-by-line consistency review of all sections; Section 3 excipient statement completed and duplicate composition note removed; wording, spelling (U.S.), units and batch-method text standardized. Revision 1.7 (2026-10-18): checked against the batch Certificate(s) of Analysis listed below; batch-documentation statements (assay, counter-ion, water and solvent content) corrected to match what the batch COAs actually report; Section 1 other means of identification completed; Section 9 completed for all Appendix D properties (color, flammability limits, vapor density, evaporation rate, particle characteristics); Section 11 interactive-effects and data-basis statements added (Appendix D 11(e), 11(g)); Section 14 environmental-hazard, bulk-transport and special-precaution entries completed; Section 15 limited to U.S. federal and state requirements (non-U.S. inventory statements removed); Section 7 storage reference limited to the product label (the batch COAs do not state storage conditions). Revision 1.6 (2026-10-03): completed manual sheet-by-sheet identity, classification, label-element, toxicology, transport and regulatory review; removed pilot and template-residue language; reconciled Sections 2, 3, 9, 11, 14 and 15.
Batch documentation reviewedSR Bio Labs COA, lot LOT-GAR6-00006, dated 2026-02-04: identity by LC-MS (mass 818.0 Da); purity 99.41% (HPLC); measured content 5.37 mg. Documentation discrepancy: the COA prints the GHRP-6 formula but reports a calculated mass of 818.0 Da and an MS signal that match GHRP-2, not GHRP-6 (873.0), and its QR code resolves to the GHRP-2 lot. The identity in this SDS follows the Loti Labs product specification. This SDS is product-level; lot-specific identity, purity and content are governed by the batch Certificate of Analysis.

Principal sources consulted

PubChem. GHRP-6, Compound Summary, CID 9919153. National Center for Biotechnology Information. https://pubchem.ncbi.nlm.nih.gov/compound/9919153. Accessed 2026-07-15.

OSHA. Hazard Communication Standard, 29 CFR 1910.1200, including Appendix D, Safety Data Sheets. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1200. Accessed 2026-07-15.

OSHA. Hazard Communication Standard Final Rule (2024). https://www.osha.gov/hazcom/rulemaking. Accessed 2026-07-15.

United Nations. Globally Harmonized System of Classification and Labelling of Chemicals, Revision 7 (2017). https://unece.org/transport/dangerous-goods/ghs-rev7-2017. Accessed 2026-07-15.

NTP. Report on Carcinogens, Fifteenth Edition. https://ntp.niehs.nih.gov/whatwestudy/assessments/cancer/roc. Accessed 2026-07-15.

IARC. Agents Classified by the IARC Monographs. https://monographs.iarc.who.int/agents-classified-by-the-iarc/. Accessed 2026-07-15.

EPA. TSCA Chemical Substance Inventory, non-confidential portion (July 2026 release). https://www.epa.gov/tsca-inventory. Accessed 2026-10-18.

OEHHA. Proposition 65 List of chemicals known to the State of California to cause cancer or reproductive toxicity (list dated July 31, 2026). https://oehha.ca.gov/proposition-65/proposition-65-list. Accessed 2026-10-18.

Key abbreviations

ACGIH, American Conference of Governmental Industrial Hygienists · BCF, Bioconcentration factor · CAS, Chemical Abstracts Service · GHS, Globally Harmonized System · IATA, International Air Transport Association · IMDG, International Maritime Dangerous Goods · NIOSH, National Institute for Occupational Safety and Health · OEL, Occupational exposure limit · OSHA, Occupational Safety and Health Administration · PPE, Personal protective equipment · STOT, Specific target organ toxicity.

16. Other information · disclaimer

The information in this Safety Data Sheet reflects the sources and product records cited as of the revision date and is provided for occupational handling of the product described.

Because substance-specific toxicological, ecotoxicological, and physical-hazard data are limited, this document uses conservative handling guidance and clearly identifies data gaps. Loti Labs does not warrant that the information is exhaustive. Users are responsible for determining suitability for their operation, conducting task-specific risk assessment, maintaining appropriate controls, and complying with all applicable federal, state, and local requirements.

This product is intended solely for scientific research and development. It is not for human or veterinary use and is not intended for food, drug, cosmetic, household, agricultural, clinical, therapeutic, or diagnostic applications.

Document review and approval

The reviewer confirmed that the supplied form, composition, hazard classification, transport classification and regulatory content of this safety data sheet were reviewed and approved for release.

Checked byDr Afroza Begum
CredentialsPhD in Biosciences
Date
SignatureAfroza Begum

Scope of review: Reviewed for content, classification, labelling and transport under 29 CFR 1910.1200 (Appendices A to D) and 49 CFR. Compound identity was checked against public references (PubChem, CAS) and the supplier’s product specification. Batch composition, purity and certificates of analysis were not verified as part of this review. Transport classification reviewed for consistency with 49 CFR; classification for shipment remains the shipper’s responsibility. Applies to version 1.8 dated 2026-10-22 only.

RESEARCH USE ONLY. Loti Labs products are supplied for laboratory, analytical and research use. They are not drugs, foods or cosmetics and are not for human or veterinary use.

All products and documentation on this site are intended strictly for research and development use only and are not for human consumption.